Academic Journal

Evaluating the accuracy and feasibility of a commercial AI-powered ergonomic assessment system for automotive assembly work.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Evaluating the accuracy and feasibility of a commercial AI-powered ergonomic assessment system for automotive assembly work.
Συγγραφείς: Zahabi SJN; Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA., Kim S; Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA., Nussbaum MA; Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA., Porto R; Advanced Ergonomics, General Motors, Detroit, MI, 28243, USA., Lim S; Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA. Electronic address: sol@vt.edu.
Πηγή: Applied ergonomics [Appl Ergon] 2026 Oct; Vol. 136, pp. 104779. Date of Electronic Publication: 2026 Apr 03.
Τύπος έκδοσης: Journal Article; Evaluation Study
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Butterworth-Heinemann Country of Publication: England NLM ID: 0261412 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1872-9126 (Electronic) Linking ISSN: 00036870 NLM ISO Abbreviation: Appl Ergon Subsets: MEDLINE
Imprint Name(s): Publication: Oxford : Butterworth-Heinemann
Original Publication: London.
Ιατρικοί όροι (MeSH): Ergonomics*/methods , Artificial Intelligence* , Automobiles*, Risk Assessment/methods ; Musculoskeletal Diseases/prevention & control ; Occupational Diseases/prevention & control ; Humans ; Motion Capture ; Feasibility Studies ; Reproducibility of Results ; Intelligent Systems ; Male ; Adult ; Female ; Software ; Task Performance and Analysis
Περίληψη: Accurate ergonomic risk assessment is essential to prevent work-related musculoskeletal disorders. Artificial intelligence (AI) and computer vision offer new opportunities for automatic risk assessment, but accuracy and usability remain uncertain. We evaluated a commercial, AI-powered, ergonomic assessment system through two studies: In an exploratory evaluation (Study 1; n = 10), we compared risk estimates and joint angles using three camera placements vs. a gold-standard 3D motion capture system. In Study 2 (n = 10), we interviewed ergonomics professionals who used the software system for automotive assembly tasks. We found substantial inaccuracies in joint angles (especially left elbow and bilateral wrists) and risk estimates, and important variability across camera setups. Although the software system was reported as easy to use and visually intuitive, concerns were noted about reliability-particularly in cluttered environments and tasks involving fine hand motions. While promising, these systems may require further refinements to improve accuracy and adaptability.
(Copyright © 2026. Published by Elsevier Ltd.)
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Contributed Indexing: Keywords: AI-Based ergonomics; Automated risk evaluation; Computer vision; Software usability
Entry Date(s): Date Created: 20260404 Date Completed: 20260714 Latest Revision: 20260714
Update Code: 20260714
DOI: 10.1016/j.apergo.2026.104779
PMID: 41934762
Βάση Δεδομένων: MEDLINE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://www.doi.org/10.1016/j.apergo.2026.104779?
    Name: ScienceDirect (all content) (s7799221)
    Category: fullText
    Text: View record from ScienceDirect
    MouseOverText: View record from ScienceDirect
  – Url: https://resolver.ebsco.com/c/fiv2js/result?sid=EBSCO:cmedm&genre=article&issn=18729126&ISBN=&volume=136&issue=&date=20261001&spage=104779&pages=104779&title=Applied ergonomics&atitle=Evaluating%20the%20accuracy%20and%20feasibility%20of%20a%20commercial%20AI-powered%20ergonomic%20assessment%20system%20for%20automotive%20assembly%20work.&aulast=Zahabi%20SJN&id=DOI:10.1016/j.apergo.2026.104779
    Name: Full Text Finder (for New FTF UI) (ns324271)
    Category: fullText
    Text: Full Text Finder
    MouseOverText: Full Text Finder
Header DbId: cmedm
DbLabel: MEDLINE
An: 41934762
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Evaluating the accuracy and feasibility of a commercial AI-powered ergonomic assessment system for automotive assembly work.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AU" term="%22Zahabi+SJN%22">Zahabi SJN</searchLink>; Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA.<br /><searchLink fieldCode="AU" term="%22Kim+S%22">Kim S</searchLink>; Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA.<br /><searchLink fieldCode="AU" term="%22Nussbaum+MA%22">Nussbaum MA</searchLink>; Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA.<br /><searchLink fieldCode="AU" term="%22Porto+R%22">Porto R</searchLink>; Advanced Ergonomics, General Motors, Detroit, MI, 28243, USA.<br /><searchLink fieldCode="AU" term="%22Lim+S%22">Lim S</searchLink>; Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA. Electronic address: sol@vt.edu.
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%220261412%22">Applied ergonomics</searchLink> [Appl Ergon] 2026 Oct; Vol. 136, pp. 104779. <i>Date of Electronic Publication: </i>2026 Apr 03.
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Journal Article; Evaluation Study
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Butterworth-Heinemann%22">Butterworth-Heinemann </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>0261412 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1872-9126 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200036870%22">00036870 </searchLink><i>NLM ISO Abbreviation: </i>Appl Ergon <i>Subsets: </i>MEDLINE
– Name: PublisherInfo
  Label: Imprint Name(s)
  Group: PubInfo
  Data: <i>Publication</i>: Oxford : Butterworth-Heinemann<br /><i>Original Publication</i>: London.
– Name: SubjectMESH
  Label: MeSH Terms
  Group: Su
  Data: <searchLink fieldCode="MM" term="%22Ergonomics%22">Ergonomics*</searchLink>/<searchLink fieldCode="MM" term="%22Ergonomics+methods%22">methods</searchLink> <br /><searchLink fieldCode="MM" term="%22Artificial+Intelligence%22">Artificial Intelligence*</searchLink> <br /><searchLink fieldCode="MM" term="%22Automobiles%22">Automobiles*</searchLink><br /><searchLink fieldCode="MH" term="%22Risk+Assessment%22">Risk Assessment</searchLink>/<searchLink fieldCode="MH" term="%22Risk+Assessment+methods%22">methods</searchLink> ; <searchLink fieldCode="MH" term="%22Musculoskeletal+Diseases%22">Musculoskeletal Diseases</searchLink>/<searchLink fieldCode="MH" term="%22Musculoskeletal+Diseases+prevention+%26+control%22">prevention & control</searchLink> ; <searchLink fieldCode="MH" term="%22Occupational+Diseases%22">Occupational Diseases</searchLink>/<searchLink fieldCode="MH" term="%22Occupational+Diseases+prevention+%26+control%22">prevention & control</searchLink> ; <searchLink fieldCode="MH" term="%22Humans%22">Humans</searchLink> ; <searchLink fieldCode="MH" term="%22Motion+Capture%22">Motion Capture</searchLink> ; <searchLink fieldCode="MH" term="%22Feasibility+Studies%22">Feasibility Studies</searchLink> ; <searchLink fieldCode="MH" term="%22Reproducibility+of+Results%22">Reproducibility of Results</searchLink> ; <searchLink fieldCode="MH" term="%22Intelligent+Systems%22">Intelligent Systems</searchLink> ; <searchLink fieldCode="MH" term="%22Male%22">Male</searchLink> ; <searchLink fieldCode="MH" term="%22Adult%22">Adult</searchLink> ; <searchLink fieldCode="MH" term="%22Female%22">Female</searchLink> ; <searchLink fieldCode="MH" term="%22Software%22">Software</searchLink> ; <searchLink fieldCode="MH" term="%22Task+Performance+and+Analysis%22">Task Performance and Analysis</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Accurate ergonomic risk assessment is essential to prevent work-related musculoskeletal disorders. Artificial intelligence (AI) and computer vision offer new opportunities for automatic risk assessment, but accuracy and usability remain uncertain. We evaluated a commercial, AI-powered, ergonomic assessment system through two studies: In an exploratory evaluation (Study 1; n = 10), we compared risk estimates and joint angles using three camera placements vs. a gold-standard 3D motion capture system. In Study 2 (n = 10), we interviewed ergonomics professionals who used the software system for automotive assembly tasks. We found substantial inaccuracies in joint angles (especially left elbow and bilateral wrists) and risk estimates, and important variability across camera setups. Although the software system was reported as easy to use and visually intuitive, concerns were noted about reliability-particularly in cluttered environments and tasks involving fine hand motions. While promising, these systems may require further refinements to improve accuracy and adaptability.<br /> (Copyright © 2026. Published by Elsevier Ltd.)
– Name: Abstract
  Label: Competing Interests
  Group: Ab
  Data: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
– Name: SubjectMinor
  Label: Contributed Indexing
  Group:
  Data: <i>Keywords: </i>AI-Based ergonomics; Automated risk evaluation; Computer vision; Software usability
– Name: DateEntry
  Label: Entry Date(s)
  Group: Date
  Data: <i>Date Created: </i>20260404 <i>Date Completed: </i>20260714 <i>Latest Revision: </i>20260714
– Name: DateUpdate
  Label: Update Code
  Group: Date
  Data: 20260714
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1016/j.apergo.2026.104779
– Name: AN
  Label: PMID
  Group: ID
  Data: 41934762
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=41934762
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.apergo.2026.104779
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        StartPage: 104779
    Subjects:
      – SubjectFull: Risk Assessment methods
        Type: general
      – SubjectFull: Musculoskeletal Diseases prevention & control
        Type: general
      – SubjectFull: Occupational Diseases prevention & control
        Type: general
      – SubjectFull: Humans
        Type: general
      – SubjectFull: Motion Capture
        Type: general
      – SubjectFull: Feasibility Studies
        Type: general
      – SubjectFull: Reproducibility of Results
        Type: general
      – SubjectFull: Intelligent Systems
        Type: general
      – SubjectFull: Male
        Type: general
      – SubjectFull: Adult
        Type: general
      – SubjectFull: Female
        Type: general
      – SubjectFull: Software
        Type: general
      – SubjectFull: Task Performance and Analysis
        Type: general
      – SubjectFull: Ergonomics methods
        Type: general
      – SubjectFull: Artificial Intelligence
        Type: general
      – SubjectFull: Automobiles
        Type: general
    Titles:
      – TitleFull: Evaluating the accuracy and feasibility of a commercial AI-powered ergonomic assessment system for automotive assembly work.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Zahabi SJN
      – PersonEntity:
          Name:
            NameFull: Kim S
      – PersonEntity:
          Name:
            NameFull: Nussbaum MA
      – PersonEntity:
          Name:
            NameFull: Porto R
      – PersonEntity:
          Name:
            NameFull: Lim S
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 10
              Text: 2026 Oct
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-electronic
              Value: 1872-9126
          Numbering:
            – Type: volume
              Value: 136
          Titles:
            – TitleFull: Applied ergonomics
              Type: main
ResultId 1