Academic Journal

Continuous Beat-to-Beat Cuffless Blood Pressure Monitoring Using Wearable Radial Artery Tonometry.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Continuous Beat-to-Beat Cuffless Blood Pressure Monitoring Using Wearable Radial Artery Tonometry.
Συγγραφείς: Almadi M, Zhu G, Zheng Y, Li Q, Yang Y, Gong JS, Strangman G, Xiang T, Liu Z, Zhang Y, Clifford GD, Zhang Q
Πηγή: IEEE transactions on bio-medical engineering [IEEE Trans Biomed Eng] 2026 Mar 25; Vol. PP. Date of Electronic Publication: 2026 Mar 25.
Publication Model: Ahead of Print
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Institute Of Electrical And Electronics Engineers Country of Publication: United States NLM ID: 0012737 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1558-2531 (Electronic) Linking ISSN: 00189294 NLM ISO Abbreviation: IEEE Trans Biomed Eng Subsets: MEDLINE
Imprint Name(s): Publication: New York, NY : Institute Of Electrical And Electronics Engineers
Original Publication: New York, IEEE Professional Technical Group on Bio-Medical Engineering.
Περίληψη: Objective: To evaluate the feasibility of continuous beat-to-beat blood pressure (BP) monitoring using radial artery tonometry under controlled dynamic conditions in healthy adults.
Methods: Twenty healthy adults participated in laboratory recordings that included seated rest and controlled dynamic challenges, including isometric handgrip, cold pressor testing, and inspiratory threshold loading. Beat-to-beat BP was estimated from the tonometry waveform, with periodic cuff-anchored drift correction and automated signal quality indices applied to exclude corrupted segments. Tonometric BP measurements were compared against a Finapres continuous noninvasive reference device.
Results: Fourteen recordings met the stability criterion (94.2 $\pm$ 6.3% data retention, approximately 42,000 accepted beats). Agreement with the reference was strong, with Pearson correlation coefficients of 0.933, 0.945, and 0.954 for systolic BP (SBP), diastolic BP (DBP), and mean arterial pressure (MAP), respectively. Corresponding mean absolute differences were 7.1 $\pm$ 5.7, 2.5 $\pm$ 2.5, and 3.8 $\pm$ 3.0 mmHg.
Conclusion: Radial artery tonometry with periodic drift correction and signal quality filtering demonstrated reliable beat-to-beat BP tracking during extended recordings that included controlled dynamic BP changes.
Significance: These findings support the feasibility of wearable radial artery tonometry for continuous cuffless BP monitoring and provide a reproducible basis for evaluating long-duration tonometric recordings under physiological stress conditions.
Grant Information: R01 EB027122 United States EB NIBIB NIH HHS
Entry Date(s): Date Created: 20260325 Latest Revision: 20260929
Update Code: 20260930
PubMed Central ID: PMC13268102
DOI: 10.1109/TBME.2026.3677590
PMID: 41880252
Βάση Δεδομένων: MEDLINE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://resolver.ebsco.com/c/fiv2js/result?sid=EBSCO:cmedm&genre=article&issn=15582531&ISBN=&volume=PP&issue=&date=20260325&spage=&pages=&title=IEEE transactions on bio-medical engineering&atitle=Continuous%20Beat-to-Beat%20Cuffless%20Blood%20Pressure%20Monitoring%20Using%20Wearable%20Radial%20Artery%20Tonometry.&aulast=Almadi%20M&id=DOI:10.1109/TBME.2026.3677590
    Name: Full Text Finder (for New FTF UI) (ns324271)
    Category: fullText
    Text: Full Text Finder
    MouseOverText: Full Text Finder
Header DbId: cmedm
DbLabel: MEDLINE
An: 41880252
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Continuous Beat-to-Beat Cuffless Blood Pressure Monitoring Using Wearable Radial Artery Tonometry.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AU" term="%22Almadi+M%22">Almadi M</searchLink><br /><searchLink fieldCode="AU" term="%22Zhu+G%22">Zhu G</searchLink><br /><searchLink fieldCode="AU" term="%22Zheng+Y%22">Zheng Y</searchLink><br /><searchLink fieldCode="AU" term="%22Li+Q%22">Li Q</searchLink><br /><searchLink fieldCode="AU" term="%22Yang+Y%22">Yang Y</searchLink><br /><searchLink fieldCode="AU" term="%22Gong+JS%22">Gong JS</searchLink><br /><searchLink fieldCode="AU" term="%22Strangman+G%22">Strangman G</searchLink><br /><searchLink fieldCode="AU" term="%22Xiang+T%22">Xiang T</searchLink><br /><searchLink fieldCode="AU" term="%22Liu+Z%22">Liu Z</searchLink><br /><searchLink fieldCode="AU" term="%22Zhang+Y%22">Zhang Y</searchLink><br /><searchLink fieldCode="AU" term="%22Clifford+GD%22">Clifford GD</searchLink><br /><searchLink fieldCode="AU" term="%22Zhang+Q%22">Zhang Q</searchLink>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%220012737%22">IEEE transactions on bio-medical engineering</searchLink> [IEEE Trans Biomed Eng] 2026 Mar 25; Vol. PP. <i>Date of Electronic Publication: </i>2026 Mar 25.
– Name: Publisher
  Label: Publication Model
  Group: PubInfo
  Data: Ahead of Print
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Journal Article
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Institute+Of+Electrical+And+Electronics+Engineers%22">Institute Of Electrical And Electronics Engineers </searchLink><i>Country of Publication: </i>United States <i>NLM ID: </i>0012737 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1558-2531 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200189294%22">00189294 </searchLink><i>NLM ISO Abbreviation: </i>IEEE Trans Biomed Eng <i>Subsets: </i>MEDLINE
– Name: PublisherInfo
  Label: Imprint Name(s)
  Group: PubInfo
  Data: <i>Publication</i>: New York, NY : Institute Of Electrical And Electronics Engineers<br /><i>Original Publication</i>: New York, IEEE Professional Technical Group on Bio-Medical Engineering.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Objective: To evaluate the feasibility of continuous beat-to-beat blood pressure (BP) monitoring using radial artery tonometry under controlled dynamic conditions in healthy adults.<br />Methods: Twenty healthy adults participated in laboratory recordings that included seated rest and controlled dynamic challenges, including isometric handgrip, cold pressor testing, and inspiratory threshold loading. Beat-to-beat BP was estimated from the tonometry waveform, with periodic cuff-anchored drift correction and automated signal quality indices applied to exclude corrupted segments. Tonometric BP measurements were compared against a Finapres continuous noninvasive reference device.<br />Results: Fourteen recordings met the stability criterion (94.2 $\pm$ 6.3% data retention, approximately 42,000 accepted beats). Agreement with the reference was strong, with Pearson correlation coefficients of 0.933, 0.945, and 0.954 for systolic BP (SBP), diastolic BP (DBP), and mean arterial pressure (MAP), respectively. Corresponding mean absolute differences were 7.1 $\pm$ 5.7, 2.5 $\pm$ 2.5, and 3.8 $\pm$ 3.0 mmHg.<br />Conclusion: Radial artery tonometry with periodic drift correction and signal quality filtering demonstrated reliable beat-to-beat BP tracking during extended recordings that included controlled dynamic BP changes.<br />Significance: These findings support the feasibility of wearable radial artery tonometry for continuous cuffless BP monitoring and provide a reproducible basis for evaluating long-duration tonometric recordings under physiological stress conditions.
– Name: GrantInfo
  Label: Grant Information
  Group: Grant
  Data: R01 EB027122 United States EB NIBIB NIH HHS
– Name: DateEntry
  Label: Entry Date(s)
  Group: Date
  Data: <i>Date Created: </i>20260325 <i>Latest Revision: </i>20260929
– Name: DateUpdate
  Label: Update Code
  Group: Date
  Data: 20260930
– Name: PubmedCentralID
  Label: PubMed Central ID
  Group: ID
  Data: PMC13268102
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1109/TBME.2026.3677590
– Name: AN
  Label: PMID
  Group: ID
  Data: 41880252
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=41880252
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1109/TBME.2026.3677590
    Languages:
      – Code: eng
        Text: English
    Titles:
      – TitleFull: Continuous Beat-to-Beat Cuffless Blood Pressure Monitoring Using Wearable Radial Artery Tonometry.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Almadi M
      – PersonEntity:
          Name:
            NameFull: Zhu G
      – PersonEntity:
          Name:
            NameFull: Zheng Y
      – PersonEntity:
          Name:
            NameFull: Li Q
      – PersonEntity:
          Name:
            NameFull: Yang Y
      – PersonEntity:
          Name:
            NameFull: Gong JS
      – PersonEntity:
          Name:
            NameFull: Strangman G
      – PersonEntity:
          Name:
            NameFull: Xiang T
      – PersonEntity:
          Name:
            NameFull: Liu Z
      – PersonEntity:
          Name:
            NameFull: Zhang Y
      – PersonEntity:
          Name:
            NameFull: Clifford GD
      – PersonEntity:
          Name:
            NameFull: Zhang Q
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 25
              M: 03
              Text: 2026 Mar 25
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-electronic
              Value: 1558-2531
          Numbering:
            – Type: volume
              Value: PP
          Titles:
            – TitleFull: IEEE transactions on bio-medical engineering
              Type: main
ResultId 1