Academic Journal
Continuous Beat-to-Beat Cuffless Blood Pressure Monitoring Using Wearable Radial Artery Tonometry.
| Τίτλος: | Continuous Beat-to-Beat Cuffless Blood Pressure Monitoring Using Wearable Radial Artery Tonometry. |
|---|---|
| Συγγραφείς: | Almadi M, Zhu G, Zheng Y, Li Q, Yang Y, Gong JS, Strangman G, Xiang T, Liu Z, Zhang Y, Clifford GD, Zhang Q |
| Πηγή: | IEEE transactions on bio-medical engineering [IEEE Trans Biomed Eng] 2026 Mar 25; Vol. PP. Date of Electronic Publication: 2026 Mar 25. |
| Publication Model: | Ahead of Print |
| Τύπος έκδοσης: | Journal Article |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: Institute Of Electrical And Electronics Engineers Country of Publication: United States NLM ID: 0012737 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1558-2531 (Electronic) Linking ISSN: 00189294 NLM ISO Abbreviation: IEEE Trans Biomed Eng Subsets: MEDLINE |
| Imprint Name(s): | Publication: New York, NY : Institute Of Electrical And Electronics Engineers Original Publication: New York, IEEE Professional Technical Group on Bio-Medical Engineering. |
| Περίληψη: | Objective: To evaluate the feasibility of continuous beat-to-beat blood pressure (BP) monitoring using radial artery tonometry under controlled dynamic conditions in healthy adults. Methods: Twenty healthy adults participated in laboratory recordings that included seated rest and controlled dynamic challenges, including isometric handgrip, cold pressor testing, and inspiratory threshold loading. Beat-to-beat BP was estimated from the tonometry waveform, with periodic cuff-anchored drift correction and automated signal quality indices applied to exclude corrupted segments. Tonometric BP measurements were compared against a Finapres continuous noninvasive reference device. Results: Fourteen recordings met the stability criterion (94.2 $\pm$ 6.3% data retention, approximately 42,000 accepted beats). Agreement with the reference was strong, with Pearson correlation coefficients of 0.933, 0.945, and 0.954 for systolic BP (SBP), diastolic BP (DBP), and mean arterial pressure (MAP), respectively. Corresponding mean absolute differences were 7.1 $\pm$ 5.7, 2.5 $\pm$ 2.5, and 3.8 $\pm$ 3.0 mmHg. Conclusion: Radial artery tonometry with periodic drift correction and signal quality filtering demonstrated reliable beat-to-beat BP tracking during extended recordings that included controlled dynamic BP changes. Significance: These findings support the feasibility of wearable radial artery tonometry for continuous cuffless BP monitoring and provide a reproducible basis for evaluating long-duration tonometric recordings under physiological stress conditions. |
| Grant Information: | R01 EB027122 United States EB NIBIB NIH HHS |
| Entry Date(s): | Date Created: 20260325 Latest Revision: 20260929 |
| Update Code: | 20260930 |
| PubMed Central ID: | PMC13268102 |
| DOI: | 10.1109/TBME.2026.3677590 |
| PMID: | 41880252 |
| Βάση Δεδομένων: | MEDLINE |
| FullText | Text: Availability: 0 CustomLinks: – Url: https://resolver.ebsco.com/c/fiv2js/result?sid=EBSCO:cmedm&genre=article&issn=15582531&ISBN=&volume=PP&issue=&date=20260325&spage=&pages=&title=IEEE transactions on bio-medical engineering&atitle=Continuous%20Beat-to-Beat%20Cuffless%20Blood%20Pressure%20Monitoring%20Using%20Wearable%20Radial%20Artery%20Tonometry.&aulast=Almadi%20M&id=DOI:10.1109/TBME.2026.3677590 Name: Full Text Finder (for New FTF UI) (ns324271) Category: fullText Text: Full Text Finder MouseOverText: Full Text Finder |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 41880252 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Continuous Beat-to-Beat Cuffless Blood Pressure Monitoring Using Wearable Radial Artery Tonometry. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Almadi+M%22">Almadi M</searchLink><br /><searchLink fieldCode="AU" term="%22Zhu+G%22">Zhu G</searchLink><br /><searchLink fieldCode="AU" term="%22Zheng+Y%22">Zheng Y</searchLink><br /><searchLink fieldCode="AU" term="%22Li+Q%22">Li Q</searchLink><br /><searchLink fieldCode="AU" term="%22Yang+Y%22">Yang Y</searchLink><br /><searchLink fieldCode="AU" term="%22Gong+JS%22">Gong JS</searchLink><br /><searchLink fieldCode="AU" term="%22Strangman+G%22">Strangman G</searchLink><br /><searchLink fieldCode="AU" term="%22Xiang+T%22">Xiang T</searchLink><br /><searchLink fieldCode="AU" term="%22Liu+Z%22">Liu Z</searchLink><br /><searchLink fieldCode="AU" term="%22Zhang+Y%22">Zhang Y</searchLink><br /><searchLink fieldCode="AU" term="%22Clifford+GD%22">Clifford GD</searchLink><br /><searchLink fieldCode="AU" term="%22Zhang+Q%22">Zhang Q</searchLink> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%220012737%22">IEEE transactions on bio-medical engineering</searchLink> [IEEE Trans Biomed Eng] 2026 Mar 25; Vol. PP. <i>Date of Electronic Publication: </i>2026 Mar 25. – Name: Publisher Label: Publication Model Group: PubInfo Data: Ahead of Print – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Institute+Of+Electrical+And+Electronics+Engineers%22">Institute Of Electrical And Electronics Engineers </searchLink><i>Country of Publication: </i>United States <i>NLM ID: </i>0012737 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1558-2531 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2200189294%22">00189294 </searchLink><i>NLM ISO Abbreviation: </i>IEEE Trans Biomed Eng <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Publication</i>: New York, NY : Institute Of Electrical And Electronics Engineers<br /><i>Original Publication</i>: New York, IEEE Professional Technical Group on Bio-Medical Engineering. – Name: Abstract Label: Abstract Group: Ab Data: Objective: To evaluate the feasibility of continuous beat-to-beat blood pressure (BP) monitoring using radial artery tonometry under controlled dynamic conditions in healthy adults.<br />Methods: Twenty healthy adults participated in laboratory recordings that included seated rest and controlled dynamic challenges, including isometric handgrip, cold pressor testing, and inspiratory threshold loading. Beat-to-beat BP was estimated from the tonometry waveform, with periodic cuff-anchored drift correction and automated signal quality indices applied to exclude corrupted segments. Tonometric BP measurements were compared against a Finapres continuous noninvasive reference device.<br />Results: Fourteen recordings met the stability criterion (94.2 $\pm$ 6.3% data retention, approximately 42,000 accepted beats). Agreement with the reference was strong, with Pearson correlation coefficients of 0.933, 0.945, and 0.954 for systolic BP (SBP), diastolic BP (DBP), and mean arterial pressure (MAP), respectively. Corresponding mean absolute differences were 7.1 $\pm$ 5.7, 2.5 $\pm$ 2.5, and 3.8 $\pm$ 3.0 mmHg.<br />Conclusion: Radial artery tonometry with periodic drift correction and signal quality filtering demonstrated reliable beat-to-beat BP tracking during extended recordings that included controlled dynamic BP changes.<br />Significance: These findings support the feasibility of wearable radial artery tonometry for continuous cuffless BP monitoring and provide a reproducible basis for evaluating long-duration tonometric recordings under physiological stress conditions. – Name: GrantInfo Label: Grant Information Group: Grant Data: R01 EB027122 United States EB NIBIB NIH HHS – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20260325 <i>Latest Revision: </i>20260929 – Name: DateUpdate Label: Update Code Group: Date Data: 20260930 – Name: PubmedCentralID Label: PubMed Central ID Group: ID Data: PMC13268102 – Name: DOI Label: DOI Group: ID Data: 10.1109/TBME.2026.3677590 – Name: AN Label: PMID Group: ID Data: 41880252 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=41880252 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1109/TBME.2026.3677590 Languages: – Code: eng Text: English Titles: – TitleFull: Continuous Beat-to-Beat Cuffless Blood Pressure Monitoring Using Wearable Radial Artery Tonometry. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Almadi M – PersonEntity: Name: NameFull: Zhu G – PersonEntity: Name: NameFull: Zheng Y – PersonEntity: Name: NameFull: Li Q – PersonEntity: Name: NameFull: Yang Y – PersonEntity: Name: NameFull: Gong JS – PersonEntity: Name: NameFull: Strangman G – PersonEntity: Name: NameFull: Xiang T – PersonEntity: Name: NameFull: Liu Z – PersonEntity: Name: NameFull: Zhang Y – PersonEntity: Name: NameFull: Clifford GD – PersonEntity: Name: NameFull: Zhang Q IsPartOfRelationships: – BibEntity: Dates: – D: 25 M: 03 Text: 2026 Mar 25 Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1558-2531 Numbering: – Type: volume Value: PP Titles: – TitleFull: IEEE transactions on bio-medical engineering Type: main |
| ResultId | 1 |