Rapid early battery depletion and lead-electrode corrosion owing to CIED gate oxide semiconductor defects.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Rapid early battery depletion and lead-electrode corrosion owing to CIED gate oxide semiconductor defects.
Συγγραφείς: Hauser RG; Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota. Electronic address: rhauser747@gmail.com., Witt D; Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota., Kapphahn-Bergs M; Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota., Sengupta JD; Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota.
Πηγή: Heart rhythm [Heart Rhythm] 2026 Sep; Vol. 23 (9), pp. 1992-1999. Date of Electronic Publication: 2026 Feb 26.
Τύπος έκδοσης: Journal Article; Research Support, Non-U.S. Gov't
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Elsevier Country of Publication: United States NLM ID: 101200317 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1556-3871 (Electronic) Linking ISSN: 15475271 NLM ISO Abbreviation: Heart Rhythm Subsets: MEDLINE
Imprint Name(s): Original Publication: New York, NY : Elsevier, c2004-
Ιατρικοί όροι (MeSH): Defibrillators, Implantable*/adverse effects , Pacemaker, Artificial*/adverse effects , Electrodes, Implanted*/adverse effects , Equipment Failure* , Electric Power Supplies* , Semiconductors*, Humans ; Corrosion ; Equipment Design ; Equipment Failure Analysis
Περίληψη: Background: Cardiac implantable electronic devices (CIEDs) rely on metal-oxide-semiconductor gating transistors to control pacing pulse delivery. Gate oxide (GO) defects can produce high leakage currents that compromise battery longevity, electronic circuit function, and lead-electrode integrity.
Objective: This study aimed to assess manufacturers' reports of CIED GO failures, characterizing their presentation, timing, clinical impact, and findings from engineering analyses of explanted devices.
Methods: We searched the Food and Drug Administration's publicly available Manufacturer and User Facility Device Experience database for reports containing the terms "gate oxide" or "oxide" submitted by Abbott, Biotronik, Boston Scientific, and Medtronic.
Results: We identified 178 GO failures reported for Boston Scientific devices (2011-2025) and 30 for Medtronic devices (2009-2021); none were reported for Abbott or Biotronik. The median time to failure was 5.8 months (interquartile range [IQR] 2.9-11.6). Pacemakers failed earlier (median 4.7 months; IQR 2.8-8.5) than implantable cardioverter-defibrillators (10.0 months; IQR 5.6-18.8). Presenting findings included premature battery depletion (n = 83), safety mode activation (n = 45), low lead impedance (n = 57), loss of telemetry (n = 25), and high power consumption (n = 21). Engineering analyses identified lead-electrode corrosion in 10 explanted leads, with electrical discontinuity in 4. Major adverse events included death (n = 2), cardiac arrest/asystole/shock (n = 5), syncope (n = 7), and heart failure (n = 6).
Conclusion: GO defects represent an early, manufacturing-related semiconductor failure mechanism in CIEDs that can rapidly deplete batteries, disable lifesaving therapy, and contribute to lead-electrode corrosion. Early recognition of characteristic device and clinical patterns may facilitate risk mitigation, particularly in vulnerable patients.
(Copyright © 2026 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.)
Competing Interests: Disclosures The authors have no conflicts of interest to disclose.
Contributed Indexing: Keywords: Battery; Corrosion; Failure; Impedance; Lead; Premature; Reliability
Entry Date(s): Date Created: 20260227 Date Completed: 20260826 Latest Revision: 20260829
Update Code: 20260830
DOI: 10.1016/j.hrthm.2026.02.037
PMID: 41759871
Βάση Δεδομένων: MEDLINE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://www.doi.org/10.1016/j.hrthm.2026.02.037?
    Name: ScienceDirect (all content) (s7799221)
    Category: fullText
    Text: View record from ScienceDirect
    MouseOverText: View record from ScienceDirect
Header DbId: cmedm
DbLabel: MEDLINE
An: 41759871
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Rapid early battery depletion and lead-electrode corrosion owing to CIED gate oxide semiconductor defects.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AU" term="%22Hauser+RG%22">Hauser RG</searchLink>; Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota. Electronic address: rhauser747@gmail.com.<br /><searchLink fieldCode="AU" term="%22Witt+D%22">Witt D</searchLink>; Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota.<br /><searchLink fieldCode="AU" term="%22Kapphahn-Bergs+M%22">Kapphahn-Bergs M</searchLink>; Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota.<br /><searchLink fieldCode="AU" term="%22Sengupta+JD%22">Sengupta JD</searchLink>; Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota.
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22101200317%22">Heart rhythm</searchLink> [Heart Rhythm] 2026 Sep; Vol. 23 (9), pp. 1992-1999. <i>Date of Electronic Publication: </i>2026 Feb 26.
– Name: TypePub
  Label: Publication Type
  Group: TypPub
  Data: Journal Article; Research Support, Non-U.S. Gov't
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: TitleSource
  Label: Journal Info
  Group: Src
  Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Elsevier%22">Elsevier </searchLink><i>Country of Publication: </i>United States <i>NLM ID: </i>101200317 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1556-3871 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2215475271%22">15475271 </searchLink><i>NLM ISO Abbreviation: </i>Heart Rhythm <i>Subsets: </i>MEDLINE
– Name: PublisherInfo
  Label: Imprint Name(s)
  Group: PubInfo
  Data: <i>Original Publication</i>: New York, NY : Elsevier, c2004-
– Name: SubjectMESH
  Label: MeSH Terms
  Group: Su
  Data: <searchLink fieldCode="MM" term="%22Defibrillators%2C+Implantable%22">Defibrillators, Implantable*</searchLink>/<searchLink fieldCode="MM" term="%22Defibrillators%2C+Implantable+adverse+effects%22">adverse effects</searchLink> <br /><searchLink fieldCode="MM" term="%22Pacemaker%2C+Artificial%22">Pacemaker, Artificial*</searchLink>/<searchLink fieldCode="MM" term="%22Pacemaker%2C+Artificial+adverse+effects%22">adverse effects</searchLink> <br /><searchLink fieldCode="MM" term="%22Electrodes%2C+Implanted%22">Electrodes, Implanted*</searchLink>/<searchLink fieldCode="MM" term="%22Electrodes%2C+Implanted+adverse+effects%22">adverse effects</searchLink> <br /><searchLink fieldCode="MM" term="%22Equipment+Failure%22">Equipment Failure*</searchLink> <br /><searchLink fieldCode="MM" term="%22Electric+Power+Supplies%22">Electric Power Supplies*</searchLink> <br /><searchLink fieldCode="MM" term="%22Semiconductors%22">Semiconductors*</searchLink><br /><searchLink fieldCode="MH" term="%22Humans%22">Humans</searchLink> ; <searchLink fieldCode="MH" term="%22Corrosion%22">Corrosion</searchLink> ; <searchLink fieldCode="MH" term="%22Equipment+Design%22">Equipment Design</searchLink> ; <searchLink fieldCode="MH" term="%22Equipment+Failure+Analysis%22">Equipment Failure Analysis</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: Cardiac implantable electronic devices (CIEDs) rely on metal-oxide-semiconductor gating transistors to control pacing pulse delivery. Gate oxide (GO) defects can produce high leakage currents that compromise battery longevity, electronic circuit function, and lead-electrode integrity.<br />Objective: This study aimed to assess manufacturers' reports of CIED GO failures, characterizing their presentation, timing, clinical impact, and findings from engineering analyses of explanted devices.<br />Methods: We searched the Food and Drug Administration's publicly available Manufacturer and User Facility Device Experience database for reports containing the terms "gate oxide" or "oxide" submitted by Abbott, Biotronik, Boston Scientific, and Medtronic.<br />Results: We identified 178 GO failures reported for Boston Scientific devices (2011-2025) and 30 for Medtronic devices (2009-2021); none were reported for Abbott or Biotronik. The median time to failure was 5.8 months (interquartile range [IQR] 2.9-11.6). Pacemakers failed earlier (median 4.7 months; IQR 2.8-8.5) than implantable cardioverter-defibrillators (10.0 months; IQR 5.6-18.8). Presenting findings included premature battery depletion (n = 83), safety mode activation (n = 45), low lead impedance (n = 57), loss of telemetry (n = 25), and high power consumption (n = 21). Engineering analyses identified lead-electrode corrosion in 10 explanted leads, with electrical discontinuity in 4. Major adverse events included death (n = 2), cardiac arrest/asystole/shock (n = 5), syncope (n = 7), and heart failure (n = 6).<br />Conclusion: GO defects represent an early, manufacturing-related semiconductor failure mechanism in CIEDs that can rapidly deplete batteries, disable lifesaving therapy, and contribute to lead-electrode corrosion. Early recognition of characteristic device and clinical patterns may facilitate risk mitigation, particularly in vulnerable patients.<br /> (Copyright © 2026 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.)
– Name: Abstract
  Label: Competing Interests
  Group: Ab
  Data: Disclosures The authors have no conflicts of interest to disclose.
– Name: SubjectMinor
  Label: Contributed Indexing
  Group:
  Data: <i>Keywords: </i>Battery; Corrosion; Failure; Impedance; Lead; Premature; Reliability
– Name: DateEntry
  Label: Entry Date(s)
  Group: Date
  Data: <i>Date Created: </i>20260227 <i>Date Completed: </i>20260826 <i>Latest Revision: </i>20260829
– Name: DateUpdate
  Label: Update Code
  Group: Date
  Data: 20260830
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1016/j.hrthm.2026.02.037
– Name: AN
  Label: PMID
  Group: ID
  Data: 41759871
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=41759871
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.hrthm.2026.02.037
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        StartPage: 1992
    Subjects:
      – SubjectFull: Humans
        Type: general
      – SubjectFull: Corrosion
        Type: general
      – SubjectFull: Equipment Design
        Type: general
      – SubjectFull: Equipment Failure Analysis
        Type: general
      – SubjectFull: Defibrillators, Implantable adverse effects
        Type: general
      – SubjectFull: Pacemaker, Artificial adverse effects
        Type: general
      – SubjectFull: Electrodes, Implanted adverse effects
        Type: general
      – SubjectFull: Equipment Failure
        Type: general
      – SubjectFull: Electric Power Supplies
        Type: general
      – SubjectFull: Semiconductors
        Type: general
    Titles:
      – TitleFull: Rapid early battery depletion and lead-electrode corrosion owing to CIED gate oxide semiconductor defects.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Hauser RG
      – PersonEntity:
          Name:
            NameFull: Witt D
      – PersonEntity:
          Name:
            NameFull: Kapphahn-Bergs M
      – PersonEntity:
          Name:
            NameFull: Sengupta JD
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: 2026 Sep
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-electronic
              Value: 1556-3871
          Numbering:
            – Type: volume
              Value: 23
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: Heart rhythm
              Type: main
ResultId 1