Academic Journal
The impact of barcode-assisted medication administration on medication administration errors in non-unit-dose settings: A systematic review.
| Τίτλος: | The impact of barcode-assisted medication administration on medication administration errors in non-unit-dose settings: A systematic review. |
|---|---|
| Συγγραφείς: | Tan W; Faculty of Information Technology, Monash University, Clayton, Victoria, Australia., Bingham G; Allied Health and Nursing Services, Alfred Health, Melbourne, Victoria, Australia., Tong E; Pharmacy, Alfred Health, Melbourne, Victoria, Australia., Shakibaei Bonakdeh E; Department of Management, Monash Business School, Monash University, Caulfield, Victoria, Australia., Wang W; Faculty of Information Technology, Monash University, Clayton, Victoria, Australia. |
| Πηγή: | Contemporary nurse [Contemp Nurse] 2026 Feb; Vol. 62 (1), pp. 109-120. Date of Electronic Publication: 2025 Nov 27. |
| Τύπος έκδοσης: | Journal Article; Systematic Review |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: Taylor & Francis Country of Publication: United States NLM ID: 9211867 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1839-3535 (Electronic) Linking ISSN: 10376178 NLM ISO Abbreviation: Contemp Nurse Subsets: MEDLINE |
| Imprint Name(s): | Publication: 2015- : Philadelphia, PA : Taylor & Francis Original Publication: [Salisbury East?] : Hyde Park Press, [1992- |
| Ιατρικοί όροι (MeSH): | Medication Errors*/prevention & control , Medication Errors*/statistics & numerical data , Medication Systems, Hospital* , Electronic Data Processing*, Humans ; Male ; Female ; Middle Aged ; Adult |
| Περίληψη: | Objective: This study aims to investigate how barcode-assisted medication administration systems (BCMAs) can affect medication administration errors (MAEs) in non-unit-dose dispensing settings, since unit-dose dispensing practice can be a confounding variable affecting MAE rates. Materials and Methods: We conducted a systematic review of English articles on MEDLINE, EMBASE, EMCARE, CINAHL and Scopus, with the most recent search conducted on 1 February, 2024. Studies were meticulously examined to exclude those with unit-dose dispensing settings.We used ROBINS-I V2 for risk-of-bias assessment and narrative synthesis to summarise findings. Results: We included 4 papers in the review. The categories of MAEs reported among these studies are heterogeneous. Two studies give weak evidence, and 1 study gives moderate evidence that BCMA can lower some categories of MAEs. 1 study gives weak evidence that BCMA increases the wrong administration time error. Discussion: Studies provide weak to moderate evidence that barcode-assisted medication administration can lower certain categories of medication administration errors. However, some reported findings are minimal. Conclusion: More multi-ward, multi-hospital studies need to be conducted to provide stronger evidence on BCMA's impact on MAEs, especially on dosage-related MAEs, in settings without unit dose dispensing practices. |
| Contributed Indexing: | Keywords: barcode-assisted medication administration; medication errors |
| Entry Date(s): | Date Created: 20251127 Date Completed: 20260416 Latest Revision: 20260609 |
| Update Code: | 20260610 |
| DOI: | 10.1080/10376178.2025.2588254 |
| PMID: | 41308039 |
| Βάση Δεδομένων: | MEDLINE |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 41308039 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: The impact of barcode-assisted medication administration on medication administration errors in non-unit-dose settings: A systematic review. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Tan+W%22">Tan W</searchLink>; Faculty of Information Technology, Monash University, Clayton, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Bingham+G%22">Bingham G</searchLink>; Allied Health and Nursing Services, Alfred Health, Melbourne, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Tong+E%22">Tong E</searchLink>; Pharmacy, Alfred Health, Melbourne, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Shakibaei+Bonakdeh+E%22">Shakibaei Bonakdeh E</searchLink>; Department of Management, Monash Business School, Monash University, Caulfield, Victoria, Australia.<br /><searchLink fieldCode="AU" term="%22Wang+W%22">Wang W</searchLink>; Faculty of Information Technology, Monash University, Clayton, Victoria, Australia. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%229211867%22">Contemporary nurse</searchLink> [Contemp Nurse] 2026 Feb; Vol. 62 (1), pp. 109-120. <i>Date of Electronic Publication: </i>2025 Nov 27. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article; Systematic Review – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Taylor+%26+Francis%22">Taylor & Francis </searchLink><i>Country of Publication: </i>United States <i>NLM ID: </i>9211867 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1839-3535 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2210376178%22">10376178 </searchLink><i>NLM ISO Abbreviation: </i>Contemp Nurse <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Publication</i>: 2015- : Philadelphia, PA : Taylor & Francis<br /><i>Original Publication</i>: [Salisbury East?] : Hyde Park Press, [1992- – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Medication+Errors%22">Medication Errors*</searchLink>/<searchLink fieldCode="MM" term="%22Medication+Errors+prevention+%26+control%22">prevention & control</searchLink> <br /><searchLink fieldCode="MM" term="%22Medication+Errors%22">Medication Errors*</searchLink>/<searchLink fieldCode="MM" term="%22Medication+Errors+statistics+%26+numerical+data%22">statistics & numerical data</searchLink> <br /><searchLink fieldCode="MM" term="%22Medication+Systems%2C+Hospital%22">Medication Systems, Hospital*</searchLink> <br /><searchLink fieldCode="MM" term="%22Electronic+Data+Processing%22">Electronic Data Processing*</searchLink><br /><searchLink fieldCode="MH" term="%22Humans%22">Humans</searchLink> ; <searchLink fieldCode="MH" term="%22Male%22">Male</searchLink> ; <searchLink fieldCode="MH" term="%22Female%22">Female</searchLink> ; <searchLink fieldCode="MH" term="%22Middle+Aged%22">Middle Aged</searchLink> ; <searchLink fieldCode="MH" term="%22Adult%22">Adult</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Objective: This study aims to investigate how barcode-assisted medication administration systems (BCMAs) can affect medication administration errors (MAEs) in non-unit-dose dispensing settings, since unit-dose dispensing practice can be a confounding variable affecting MAE rates.<br />Materials and Methods: We conducted a systematic review of English articles on MEDLINE, EMBASE, EMCARE, CINAHL and Scopus, with the most recent search conducted on 1 February, 2024. Studies were meticulously examined to exclude those with unit-dose dispensing settings.We used ROBINS-I V2 for risk-of-bias assessment and narrative synthesis to summarise findings.<br />Results: We included 4 papers in the review. The categories of MAEs reported among these studies are heterogeneous. Two studies give weak evidence, and 1 study gives moderate evidence that BCMA can lower some categories of MAEs. 1 study gives weak evidence that BCMA increases the wrong administration time error.<br />Discussion: Studies provide weak to moderate evidence that barcode-assisted medication administration can lower certain categories of medication administration errors. However, some reported findings are minimal.<br />Conclusion: More multi-ward, multi-hospital studies need to be conducted to provide stronger evidence on BCMA's impact on MAEs, especially on dosage-related MAEs, in settings without unit dose dispensing practices. – Name: SubjectMinor Label: Contributed Indexing Group: Data: <i>Keywords: </i>barcode-assisted medication administration; medication errors – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20251127 <i>Date Completed: </i>20260416 <i>Latest Revision: </i>20260609 – Name: DateUpdate Label: Update Code Group: Date Data: 20260610 – Name: DOI Label: DOI Group: ID Data: 10.1080/10376178.2025.2588254 – Name: AN Label: PMID Group: ID Data: 41308039 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=41308039 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1080/10376178.2025.2588254 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 109 Subjects: – SubjectFull: Humans Type: general – SubjectFull: Male Type: general – SubjectFull: Female Type: general – SubjectFull: Middle Aged Type: general – SubjectFull: Adult Type: general – SubjectFull: Medication Errors prevention & control Type: general – SubjectFull: Medication Errors statistics & numerical data Type: general – SubjectFull: Medication Systems, Hospital Type: general – SubjectFull: Electronic Data Processing Type: general Titles: – TitleFull: The impact of barcode-assisted medication administration on medication administration errors in non-unit-dose settings: A systematic review. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Tan W – PersonEntity: Name: NameFull: Bingham G – PersonEntity: Name: NameFull: Tong E – PersonEntity: Name: NameFull: Shakibaei Bonakdeh E – PersonEntity: Name: NameFull: Wang W IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 02 Text: 2026 Feb Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 1839-3535 Numbering: – Type: volume Value: 62 – Type: issue Value: 1 Titles: – TitleFull: Contemporary nurse Type: main |
| ResultId | 1 |