Academic Journal
Tactile Enhancement of Mid-Air Ultrasonic Stimulation by Wrist Vibration: Perceived Intensity and Pattern Recognition.
| Τίτλος: | Tactile Enhancement of Mid-Air Ultrasonic Stimulation by Wrist Vibration: Perceived Intensity and Pattern Recognition. |
|---|---|
| Συγγραφείς: | Kim DG, Choi S |
| Πηγή: | IEEE transactions on haptics [IEEE Trans Haptics] 2025 Jul-Sep; Vol. 18 (3), pp. 603-614. |
| Τύπος έκδοσης: | Journal Article |
| Γλώσσα: | English |
| Στοιχεία περιοδικού: | Publisher: IEEE Computer Society Country of Publication: United States NLM ID: 101491191 Publication Model: Print Cited Medium: Internet ISSN: 2329-4051 (Electronic) Linking ISSN: 19391412 NLM ISO Abbreviation: IEEE Trans Haptics Subsets: MEDLINE |
| Imprint Name(s): | Original Publication: New York : IEEE Computer Society, c2008- |
| Ιατρικοί όροι (MeSH): | Touch Perception*/physiology , Wrist*/physiology , Touch*/physiology , Pattern Recognition, Physiological*/physiology , Vibration* , Ultrasonic Waves*, Physical Stimulation/methods ; Humans ; Male ; Female ; Adult ; Young Adult |
| Περίληψη: | This study investigates methods to enhance the perceived intensity of mid-air ultrasonic tactile stimuli through the perceptual phenomenon of tactile enhancement. By presenting a brief vibrotactile stimulus to the wrist before stimulating the palm with a mid-air ultrasonic stimulus of the same frequency, we demonstrated that the perceived intensity could be increased by up to 1.7 times. A second user study further examined the effectiveness of this method, revealing that recognition of number-patterned mid-air stimuli was significantly improved by 7.8% with the presence of wrist vibration. These findings offer promising directions for improving the usability of mid-air haptic devices using common wearable technology. |
| Entry Date(s): | Date Created: 20250619 Date Completed: 20250919 Latest Revision: 20250922 |
| Update Code: | 20260130 |
| DOI: | 10.1109/TOH.2025.3581196 |
| PMID: | 40536858 |
| Βάση Δεδομένων: | MEDLINE |
| FullText | Links: – Type: other Url: https://resolver.ebsco.com:443/public/rma-ftfapi/ejs/direct?AccessToken=4E88991DB4E54BDC97C2&Show=Object Text: Availability: 0 |
|---|---|
| Header | DbId: cmedm DbLabel: MEDLINE An: 40536858 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Tactile Enhancement of Mid-Air Ultrasonic Stimulation by Wrist Vibration: Perceived Intensity and Pattern Recognition. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Kim+DG%22">Kim DG</searchLink><br /><searchLink fieldCode="AU" term="%22Choi+S%22">Choi S</searchLink> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22101491191%22">IEEE transactions on haptics</searchLink> [IEEE Trans Haptics] 2025 Jul-Sep; Vol. 18 (3), pp. 603-614. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: Language Label: Language Group: Lang Data: English – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22IEEE+Computer+Society%22">IEEE Computer Society </searchLink><i>Country of Publication: </i>United States <i>NLM ID: </i>101491191 <i>Publication Model: </i>Print <i>Cited Medium: </i>Internet <i>ISSN: </i>2329-4051 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2219391412%22">19391412 </searchLink><i>NLM ISO Abbreviation: </i>IEEE Trans Haptics <i>Subsets: </i>MEDLINE – Name: PublisherInfo Label: Imprint Name(s) Group: PubInfo Data: <i>Original Publication</i>: New York : IEEE Computer Society, c2008- – Name: SubjectMESH Label: MeSH Terms Group: Su Data: <searchLink fieldCode="MM" term="%22Touch+Perception%22">Touch Perception*</searchLink>/<searchLink fieldCode="MM" term="%22Touch+Perception+physiology%22">physiology</searchLink> <br /><searchLink fieldCode="MM" term="%22Wrist%22">Wrist*</searchLink>/<searchLink fieldCode="MM" term="%22Wrist+physiology%22">physiology</searchLink> <br /><searchLink fieldCode="MM" term="%22Touch%22">Touch*</searchLink>/<searchLink fieldCode="MM" term="%22Touch+physiology%22">physiology</searchLink> <br /><searchLink fieldCode="MM" term="%22Pattern+Recognition%2C+Physiological%22">Pattern Recognition, Physiological*</searchLink>/<searchLink fieldCode="MM" term="%22Pattern+Recognition%2C+Physiological+physiology%22">physiology</searchLink> <br /><searchLink fieldCode="MM" term="%22Vibration%22">Vibration*</searchLink> <br /><searchLink fieldCode="MM" term="%22Ultrasonic+Waves%22">Ultrasonic Waves*</searchLink><br /><searchLink fieldCode="MH" term="%22Physical+Stimulation%22">Physical Stimulation</searchLink>/<searchLink fieldCode="MH" term="%22Physical+Stimulation+methods%22">methods</searchLink> ; <searchLink fieldCode="MH" term="%22Humans%22">Humans</searchLink> ; <searchLink fieldCode="MH" term="%22Male%22">Male</searchLink> ; <searchLink fieldCode="MH" term="%22Female%22">Female</searchLink> ; <searchLink fieldCode="MH" term="%22Adult%22">Adult</searchLink> ; <searchLink fieldCode="MH" term="%22Young+Adult%22">Young Adult</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: This study investigates methods to enhance the perceived intensity of mid-air ultrasonic tactile stimuli through the perceptual phenomenon of tactile enhancement. By presenting a brief vibrotactile stimulus to the wrist before stimulating the palm with a mid-air ultrasonic stimulus of the same frequency, we demonstrated that the perceived intensity could be increased by up to 1.7 times. A second user study further examined the effectiveness of this method, revealing that recognition of number-patterned mid-air stimuli was significantly improved by 7.8% with the presence of wrist vibration. These findings offer promising directions for improving the usability of mid-air haptic devices using common wearable technology. – Name: DateEntry Label: Entry Date(s) Group: Date Data: <i>Date Created: </i>20250619 <i>Date Completed: </i>20250919 <i>Latest Revision: </i>20250922 – Name: DateUpdate Label: Update Code Group: Date Data: 20260130 – Name: DOI Label: DOI Group: ID Data: 10.1109/TOH.2025.3581196 – Name: AN Label: PMID Group: ID Data: 40536858 |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=cmedm&AN=40536858 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1109/TOH.2025.3581196 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 603 Subjects: – SubjectFull: Physical Stimulation methods Type: general – SubjectFull: Humans Type: general – SubjectFull: Male Type: general – SubjectFull: Female Type: general – SubjectFull: Adult Type: general – SubjectFull: Young Adult Type: general – SubjectFull: Touch Perception physiology Type: general – SubjectFull: Wrist physiology Type: general – SubjectFull: Touch physiology Type: general – SubjectFull: Pattern Recognition, Physiological physiology Type: general – SubjectFull: Vibration Type: general – SubjectFull: Ultrasonic Waves Type: general Titles: – TitleFull: Tactile Enhancement of Mid-Air Ultrasonic Stimulation by Wrist Vibration: Perceived Intensity and Pattern Recognition. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Kim DG – PersonEntity: Name: NameFull: Choi S IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 07 Text: 2025 Jul-Sep Type: published Y: 2025 Identifiers: – Type: issn-electronic Value: 2329-4051 Numbering: – Type: volume Value: 18 – Type: issue Value: 3 Titles: – TitleFull: IEEE transactions on haptics Type: main |
| ResultId | 1 |