Shear rate induced viscosity change of human blood samples and blood mimicking fluids.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Shear rate induced viscosity change of human blood samples and blood mimicking fluids.
Συγγραφείς: Szabó E; 1Department of Machine and Product Design, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary., Baka EZ; 1Department of Machine and Product Design, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary., Tamás K; 1Department of Machine and Product Design, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary.
Πηγή: Acta of bioengineering and biomechanics [Acta Bioeng Biomech] 2024 May 08; Vol. 26 (1), pp. 99-107. Date of Electronic Publication: 2024 May 08 (Print Publication: 2024).
Τύπος έκδοσης: Journal Article
Γλώσσα: English
Στοιχεία περιοδικού: Publisher: Sciendo Country of Publication: Poland NLM ID: 101194794 Publication Model: Electronic-Print Cited Medium: Internet ISSN: 2450-6303 (Electronic) Linking ISSN: 1509409X NLM ISO Abbreviation: Acta Bioeng Biomech Subsets: MEDLINE
Imprint Name(s): Publication: 2023- : Warsaw, Poland : Sciendo
Original Publication: Wrocław : Oficyna Wydawnicza Politechniki Wrocławskiej, 1999-
Ιατρικοί όροι (MeSH): Blood Viscosity*, Humans ; Shear Strength ; Stress, Mechanical ; Viscosity
Περίληψη: Purpose: The aim of this study was to measure blood and blood mimicking fluids viscosity at different shear rates (on the interval of 0.1-5000 1/s and 0.1-10000 1/s) while taking into consideration the measuring device's capability and blood's characteristics. We also provided the measurement results of the most accurate measuring program. Methods: We measured blood samples from five donors, and four different blood mimicking fluid compositions. The measurements were done on an Anton Paar Physica MCR301 rotational rheometer with two measuring programs varying in the shear rate intervals, the number of measuring points and the measuring point durations. Results: The results confirmed the significant shear thinning and thixotropic effects of blood. Blood mimicking fluids also had these characteristics. The measured blood viscosity values are in agreement with those of the literature. Conclusions: It can be concluded that the step test program was able to give more stable results as the measured torque was over the nominal limit of 0.05 ìNm over 0.1 1/s and over the selected torque limit of 0.5 ìNm over 31.6 1/s. Blood mimicking fluid measurement results were different from that of the literature due to different measuring conditions. The sample consisting of water, glycerol and starch mimicked well blood's behaviour and viscosity values at 37 degrees Celsius.
(© 2024 Eszter Szabó et al., published by Sciendo.)
References: Anton Paar GmbH, RheoPlus Rheometer Software. Instruction Manual., Anton Paar GmbH, 2005.
B illett H.H., Hemoglobin and hematocrit, Clinical Methods: The History, Physical, and Laboratory Examinations , 3rd Ed., Butterworth Publishers, 1990.
B iro G.P., Comparison of acute cardiovascular effects and oxygen-supply following haemodilution with dextran, stroma-free haemoglobin solution and fluorocarbon suspension , Car-diovasc. Res., 1982, 16 (4), 194–204.
Devine B., Mean Blood Hematocrit of Adults , United States, 1960–1962. No. 19–24, US Department of Health, Education, and Welfare, Public Health Service, 1967.
D ong C., S kalak R., S ung K.L.P., S chmid -S chönbein G.W., C hien S., Passive deformation analysis of human leukocytes , J. Biomech. Eng., 1988, 110 (1), 27–36.
E rrill E.W., Rheology of blood , Physiol. Rev., 1969, 49 (4), 863–888.
G utterman D.D., C habowski D.S., K adlec A.O. D urand M.J., F reed J.K., A it -A issa K., B eyer A.M., The human microcirculation: regulation of flow and beyond , Circ. Res., 2016, 118 (1), 157–172.
H uang C.R., F abisiak W., Thixotropic parameters of whole human blood , Thromb. Res., 1976, 8, 1–8.
K u D.N., Blood flow in arteries , Annu. Rev. Fluid Mech., 1997, 29 (1), 399–434.
K uhnle G.E., K uebler W.M., G roh J., G oetz A.E., Effect of blood flow on the leukocyte-endothelium interaction in pulmonary microvessels , Am. J. Respir. Crit. Care Med., 1995, 152 (4), 1221–1228.
N emeth N., P eto K., M agyar Z., K larik Z., V arga G., O ltean M., M antas A., C zigany Z., T olba R.H., Hemorheological and microcirculatory factors in liver ische-mia-reperfusion injury – An update on pathophysiology, molecular mechanisms and protective strategies , Int. J. Mol. Sci., 2021, 22 (4), 1864.
P errira N., S huib A.S., P hang S.W., M uda A.S., Experimental Investigation of Blood Mimicking Fluid Viscosity for Application in 3D-Printed Medical Simulator , J. Phys. Conf. Ser., 2022, 2222 (1), 012016.
Q uemada D., Hydrodynamique sanguine: hémorhéologie et écoulement du sang dans les petits vaisseaux , J. Phys. Colloques, 1976, 37 (C1), 9–22.
R ampling M.W., Compositional properties of blood , Hand-book of Hemorheology and Hemodynamics , IOS Press, 2007, 69, 34–44.
S challer J., G erber S., K aempfer U., L ejon S., T rachsel C., Human blood plasma proteins: structure and function , John Wiley & Sons, 2008.
S kalak R., K eller S.R., S ecomb T.W., Mechanics of Blood Flow , J. Biomech. Eng., 1981, 103 (2), 102–115.
S undd P., P ospieszalska M.K., C heung L.S.L., K onstantopoulos K., L ey K., Biomechanics of leukocyte rolling , Biorheology, 2011, 48 (1), 1–35.
V iallat A., A bkarian M., Red blood cell: from its mechanics to its motion in shear flow , Int. J. Lab. Hematol., 2014, 36 (3), 237–243.
W atts S.W., K anagy N.L., L ombard J.H., Receptor-mediated events in the microcirculation , Microcirculation, Academic Press, 2008, 285–348.
Health Organization, The Top 10 Causes of Death, 2020, https://www.who.int/news-room/fact-sheets/detail/the-top-10-causes-of-death [Accessed: 04 April 2024].
Contributed Indexing: Keywords: blood; blood mimicking fluids; measurements; rheology; thixotropy; viscosity
Entry Date(s): Date Created: 20240902 Date Completed: 20240902 Latest Revision: 20250415
Update Code: 20260130
DOI: 10.37190/abb-02405-2024-03
PMID: 39219075
Βάση Δεδομένων: MEDLINE