Evaluating variability in 24-hour urine free cortisol measurements: impact of sample collection errors.
| Τίτλος: | Evaluating variability in 24-hour urine free cortisol measurements: impact of sample collection errors. |
|---|---|
| Συγγραφείς: | Özcan, Ömer1,2,3 (AUTHOR), Koops, Karlijn1,2,3 (AUTHOR), Hillebrand, Jacquelien J.2,3 (AUTHOR), van Herwaarden, Antonius E.4 (AUTHOR), van de Ven, Annenienke5 (AUTHOR), Bisschop, Peter H.2,6,7 (AUTHOR), den Elzen, Wendy P.J.2,8,9 (AUTHOR), Heijboer, Annemieke C.1,2,3,10 (AUTHOR) a.heijboer@amsterdamumc.nl |
| Πηγή: | Clinical Chemistry & Laboratory Medicine. Aug2026, p1. 6p. 2 Illustrations. |
| Θεματικοί όροι: | *Sampling errors, *Creatinine, *Metrology, *Biomarkers, *Patient education, *Cushing's syndrome |
| Περίληψη: | 24 hour urine free cortisol measurement is widely used for screening Cushing’s syndrome, but its reliability is limited by variability due to inherent biological variation and variation introduced by collection errors. This study aimed to determine the proportion of inaccurately collected samples and evaluate the impact on urine free cortisol variability.A retrospective analysis was conducted using paired 24-h urine samples from subjects screened for hypercortisolism at two academic hospitals in the Netherlands. Paired 24-h urine samples from 552 subjects were evaluated. Collection accuracy was determined by comparing creatinine and urine volume differences between consecutive samples. Samples were classified as inaccurate if the creatinine difference exceeded 4 mmol/24 h or the volume difference exceeded 55 %.19 % of paired urine collections were classified as inaccurate. Accurate collections showed lower variability in urine free cortisol concentrations (coefficient of variation 17 %) compared to inaccurate collections (coefficient of variation 33 %).This study shows that many routine 24-h urine samples are collected incorrectly. Collection errors contribute considerably to the total variability of 24-h urine free cortisol measurements. This highlights the importance of patient instruction and adherence to collection protocols for reproducibility of urine free cortisol measurements. [ABSTRACT FROM AUTHOR] |
| Βάση Δεδομένων: | Academic Search Index |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: asx DbLabel: Academic Search Index An: 196155829 RelevancyScore: 1452 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 1452.42504882813 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Evaluating variability in 24-hour urine free cortisol measurements: impact of sample collection errors. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Özcan%2C+Ömer%22">Özcan, Ömer</searchLink><relatesTo>1,2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Koops%2C+Karlijn%22">Koops, Karlijn</searchLink><relatesTo>1,2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hillebrand%2C+Jacquelien+J%2E%22">Hillebrand, Jacquelien J.</searchLink><relatesTo>2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22van+Herwaarden%2C+Antonius+E%2E%22">van Herwaarden, Antonius E.</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22van+de+Ven%2C+Annenienke%22">van de Ven, Annenienke</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bisschop%2C+Peter+H%2E%22">Bisschop, Peter H.</searchLink><relatesTo>2,6,7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22den+Elzen%2C+Wendy+P%2EJ%2E%22">den Elzen, Wendy P.J.</searchLink><relatesTo>2,8,9</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Heijboer%2C+Annemieke+C%2E%22">Heijboer, Annemieke C.</searchLink><relatesTo>1,2,3,10</relatesTo> (AUTHOR)<i> a.heijboer@amsterdamumc.nl</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Clinical+Chemistry+%26+Laboratory+Medicine%22">Clinical Chemistry & Laboratory Medicine</searchLink>. Aug2026, p1. 6p. 2 Illustrations. – Name: Subject Label: Subject Terms Group: Su Data: *<searchLink fieldCode="DE" term="%22Sampling+errors%22">Sampling errors</searchLink><br />*<searchLink fieldCode="DE" term="%22Creatinine%22">Creatinine</searchLink><br />*<searchLink fieldCode="DE" term="%22Metrology%22">Metrology</searchLink><br />*<searchLink fieldCode="DE" term="%22Biomarkers%22">Biomarkers</searchLink><br />*<searchLink fieldCode="DE" term="%22Patient+education%22">Patient education</searchLink><br />*<searchLink fieldCode="DE" term="%22Cushing's+syndrome%22">Cushing's syndrome</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: 24 hour urine free cortisol measurement is widely used for screening Cushing’s syndrome, but its reliability is limited by variability due to inherent biological variation and variation introduced by collection errors. This study aimed to determine the proportion of inaccurately collected samples and evaluate the impact on urine free cortisol variability.A retrospective analysis was conducted using paired 24-h urine samples from subjects screened for hypercortisolism at two academic hospitals in the Netherlands. Paired 24-h urine samples from 552 subjects were evaluated. Collection accuracy was determined by comparing creatinine and urine volume differences between consecutive samples. Samples were classified as inaccurate if the creatinine difference exceeded 4 mmol/24 h or the volume difference exceeded 55 %.19 % of paired urine collections were classified as inaccurate. Accurate collections showed lower variability in urine free cortisol concentrations (coefficient of variation 17 %) compared to inaccurate collections (coefficient of variation 33 %).This study shows that many routine 24-h urine samples are collected incorrectly. Collection errors contribute considerably to the total variability of 24-h urine free cortisol measurements. This highlights the importance of patient instruction and adherence to collection protocols for reproducibility of urine free cortisol measurements. [ABSTRACT FROM AUTHOR] |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=asx&AN=196155829 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1515/cclm-2026-0410 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 6 StartPage: 1 Subjects: – SubjectFull: Sampling errors Type: general – SubjectFull: Creatinine Type: general – SubjectFull: Metrology Type: general – SubjectFull: Biomarkers Type: general – SubjectFull: Patient education Type: general – SubjectFull: Cushing's syndrome Type: general Titles: – TitleFull: Evaluating variability in 24-hour urine free cortisol measurements: impact of sample collection errors. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Özcan, Ömer – PersonEntity: Name: NameFull: Koops, Karlijn – PersonEntity: Name: NameFull: Hillebrand, Jacquelien J. – PersonEntity: Name: NameFull: van Herwaarden, Antonius E. – PersonEntity: Name: NameFull: van de Ven, Annenienke – PersonEntity: Name: NameFull: Bisschop, Peter H. – PersonEntity: Name: NameFull: den Elzen, Wendy P.J. – PersonEntity: Name: NameFull: Heijboer, Annemieke C. IsPartOfRelationships: – BibEntity: Dates: – D: 17 M: 08 Text: Aug2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 14346621 Titles: – TitleFull: Clinical Chemistry & Laboratory Medicine Type: main |
| ResultId | 1 |