Academic Journal

Evaluating variability in 24-hour urine free cortisol measurements: impact of sample collection errors.

Λεπτομέρειες βιβλιογραφικής εγγραφής
Τίτλος: Evaluating variability in 24-hour urine free cortisol measurements: impact of sample collection errors.
Συγγραφείς: Özcan, Ömer1,2,3 (AUTHOR), Koops, Karlijn1,2,3 (AUTHOR), Hillebrand, Jacquelien J.2,3 (AUTHOR), van Herwaarden, Antonius E.4 (AUTHOR), van de Ven, Annenienke5 (AUTHOR), Bisschop, Peter H.2,6,7 (AUTHOR), den Elzen, Wendy P.J.2,8,9 (AUTHOR), Heijboer, Annemieke C.1,2,3,10 (AUTHOR) a.heijboer@amsterdamumc.nl
Πηγή: Clinical Chemistry & Laboratory Medicine. Aug2026, p1. 6p. 2 Illustrations.
Θεματικοί όροι: *Sampling errors, *Creatinine, *Metrology, *Biomarkers, *Patient education, *Cushing's syndrome
Περίληψη: 24 hour urine free cortisol measurement is widely used for screening Cushing’s syndrome, but its reliability is limited by variability due to inherent biological variation and variation introduced by collection errors. This study aimed to determine the proportion of inaccurately collected samples and evaluate the impact on urine free cortisol variability.A retrospective analysis was conducted using paired 24-h urine samples from subjects screened for hypercortisolism at two academic hospitals in the Netherlands. Paired 24-h urine samples from 552 subjects were evaluated. Collection accuracy was determined by comparing creatinine and urine volume differences between consecutive samples. Samples were classified as inaccurate if the creatinine difference exceeded 4 mmol/24 h or the volume difference exceeded 55 %.19 % of paired urine collections were classified as inaccurate. Accurate collections showed lower variability in urine free cortisol concentrations (coefficient of variation 17 %) compared to inaccurate collections (coefficient of variation 33 %).This study shows that many routine 24-h urine samples are collected incorrectly. Collection errors contribute considerably to the total variability of 24-h urine free cortisol measurements. This highlights the importance of patient instruction and adherence to collection protocols for reproducibility of urine free cortisol measurements. [ABSTRACT FROM AUTHOR]
Βάση Δεδομένων: Academic Search Index
FullText Text:
  Availability: 0
Header DbId: asx
DbLabel: Academic Search Index
An: 196155829
RelevancyScore: 1452
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 1452.42504882813
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Evaluating variability in 24-hour urine free cortisol measurements: impact of sample collection errors.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Özcan%2C+Ömer%22">Özcan, Ömer</searchLink><relatesTo>1,2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Koops%2C+Karlijn%22">Koops, Karlijn</searchLink><relatesTo>1,2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hillebrand%2C+Jacquelien+J%2E%22">Hillebrand, Jacquelien J.</searchLink><relatesTo>2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22van+Herwaarden%2C+Antonius+E%2E%22">van Herwaarden, Antonius E.</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22van+de+Ven%2C+Annenienke%22">van de Ven, Annenienke</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bisschop%2C+Peter+H%2E%22">Bisschop, Peter H.</searchLink><relatesTo>2,6,7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22den+Elzen%2C+Wendy+P%2EJ%2E%22">den Elzen, Wendy P.J.</searchLink><relatesTo>2,8,9</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Heijboer%2C+Annemieke+C%2E%22">Heijboer, Annemieke C.</searchLink><relatesTo>1,2,3,10</relatesTo> (AUTHOR)<i> a.heijboer@amsterdamumc.nl</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Clinical+Chemistry+%26+Laboratory+Medicine%22">Clinical Chemistry & Laboratory Medicine</searchLink>. Aug2026, p1. 6p. 2 Illustrations.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Sampling+errors%22">Sampling errors</searchLink><br />*<searchLink fieldCode="DE" term="%22Creatinine%22">Creatinine</searchLink><br />*<searchLink fieldCode="DE" term="%22Metrology%22">Metrology</searchLink><br />*<searchLink fieldCode="DE" term="%22Biomarkers%22">Biomarkers</searchLink><br />*<searchLink fieldCode="DE" term="%22Patient+education%22">Patient education</searchLink><br />*<searchLink fieldCode="DE" term="%22Cushing's+syndrome%22">Cushing's syndrome</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: 24 hour urine free cortisol measurement is widely used for screening Cushing’s syndrome, but its reliability is limited by variability due to inherent biological variation and variation introduced by collection errors. This study aimed to determine the proportion of inaccurately collected samples and evaluate the impact on urine free cortisol variability.A retrospective analysis was conducted using paired 24-h urine samples from subjects screened for hypercortisolism at two academic hospitals in the Netherlands. Paired 24-h urine samples from 552 subjects were evaluated. Collection accuracy was determined by comparing creatinine and urine volume differences between consecutive samples. Samples were classified as inaccurate if the creatinine difference exceeded 4 mmol/24 h or the volume difference exceeded 55 %.19 % of paired urine collections were classified as inaccurate. Accurate collections showed lower variability in urine free cortisol concentrations (coefficient of variation 17 %) compared to inaccurate collections (coefficient of variation 33 %).This study shows that many routine 24-h urine samples are collected incorrectly. Collection errors contribute considerably to the total variability of 24-h urine free cortisol measurements. This highlights the importance of patient instruction and adherence to collection protocols for reproducibility of urine free cortisol measurements. [ABSTRACT FROM AUTHOR]
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=asx&AN=196155829
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1515/cclm-2026-0410
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 1
    Subjects:
      – SubjectFull: Sampling errors
        Type: general
      – SubjectFull: Creatinine
        Type: general
      – SubjectFull: Metrology
        Type: general
      – SubjectFull: Biomarkers
        Type: general
      – SubjectFull: Patient education
        Type: general
      – SubjectFull: Cushing's syndrome
        Type: general
    Titles:
      – TitleFull: Evaluating variability in 24-hour urine free cortisol measurements: impact of sample collection errors.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Özcan, Ömer
      – PersonEntity:
          Name:
            NameFull: Koops, Karlijn
      – PersonEntity:
          Name:
            NameFull: Hillebrand, Jacquelien J.
      – PersonEntity:
          Name:
            NameFull: van Herwaarden, Antonius E.
      – PersonEntity:
          Name:
            NameFull: van de Ven, Annenienke
      – PersonEntity:
          Name:
            NameFull: Bisschop, Peter H.
      – PersonEntity:
          Name:
            NameFull: den Elzen, Wendy P.J.
      – PersonEntity:
          Name:
            NameFull: Heijboer, Annemieke C.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 17
              M: 08
              Text: Aug2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 14346621
          Titles:
            – TitleFull: Clinical Chemistry & Laboratory Medicine
              Type: main
ResultId 1