Academic Journal
The Effect of Transducer High-Frequency Output on Clinically Used Speech Recognition in Noise Tests.
| Τίτλος: | The Effect of Transducer High-Frequency Output on Clinically Used Speech Recognition in Noise Tests. |
|---|---|
| Συγγραφείς: | Veeranna, Sangamanatha Ankmnal1 s.ankmnalveeranna@usm.edu, Chapmana, Jennifer1 |
| Πηγή: | American Journal of Audiology. Jun2026, Vol. 35 Issue 2, p557-564. 8p. |
| Θεματικοί όροι: | *Auditory perception testing, *Noise, *Research funding, *Data analysis, *Sensorineural hearing loss, *Product design, *Audiometric equipment, *Treatment effectiveness, *Descriptive statistics, *Audiometry, *Auditory acuity, *Age distribution, *Speech audiometry, *Statistics, *Speech perception, *Data analysis software, *Hearing, *Transducers |
| Περίληψη: | Purpose: The purpose of the present study was to determine whether standard and high-frequency transducers influence test scores on clinically used speech-in- noise (SIN) assessments, such as the Word-In-Noise (WIN) and QuickSIN tests. Method: Sixteen individuals whose hearing thresholds were within normal limits (≤ 25 dB HL at 0.5, 1, 2, and 4 kHz), and nine individuals with sensorineural hearing loss participated in this research. Hearing thresholds were obtained at extended high frequencies in adults with normal hearing. The WIN and QuickSIN tests were administered to only one ear. These tests were conducted using the RadioEar IP30 and RadioEar DD450 transducers. Results: There were no significant differences in the WIN and QuickSIN test scores between the IP30 and DD450 transducers in both groups. Analysis of WIN and QuickSIN test scores of individuals whose thresholds were within normal limits while controlling for age and extended high-frequency hearing thresholds showed no significant effect of the transducer, suggesting that these factors did not influence the test scores. Conclusion: The findings of this study suggest that both IP30 inserts and DD450 headphones are suitable for use in WIN and QuickSIN testing. [ABSTRACT FROM AUTHOR] |
| Βάση Δεδομένων: | Academic Search Index |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: asx DbLabel: Academic Search Index An: 194359730 RelevancyScore: 1511 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 1510.76538085938 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: The Effect of Transducer High-Frequency Output on Clinically Used Speech Recognition in Noise Tests. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Veeranna%2C+Sangamanatha+Ankmnal%22">Veeranna, Sangamanatha Ankmnal</searchLink><relatesTo>1</relatesTo><i> s.ankmnalveeranna@usm.edu</i><br /><searchLink fieldCode="AR" term="%22Chapmana%2C+Jennifer%22">Chapmana, Jennifer</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22American+Journal+of+Audiology%22">American Journal of Audiology</searchLink>. Jun2026, Vol. 35 Issue 2, p557-564. 8p. – Name: Subject Label: Subject Terms Group: Su Data: *<searchLink fieldCode="DE" term="%22Auditory+perception+testing%22">Auditory perception testing</searchLink><br />*<searchLink fieldCode="DE" term="%22Noise%22">Noise</searchLink><br />*<searchLink fieldCode="DE" term="%22Research+funding%22">Research funding</searchLink><br />*<searchLink fieldCode="DE" term="%22Data+analysis%22">Data analysis</searchLink><br />*<searchLink fieldCode="DE" term="%22Sensorineural+hearing+loss%22">Sensorineural hearing loss</searchLink><br />*<searchLink fieldCode="DE" term="%22Product+design%22">Product design</searchLink><br />*<searchLink fieldCode="DE" term="%22Audiometric+equipment%22">Audiometric equipment</searchLink><br />*<searchLink fieldCode="DE" term="%22Treatment+effectiveness%22">Treatment effectiveness</searchLink><br />*<searchLink fieldCode="DE" term="%22Descriptive+statistics%22">Descriptive statistics</searchLink><br />*<searchLink fieldCode="DE" term="%22Audiometry%22">Audiometry</searchLink><br />*<searchLink fieldCode="DE" term="%22Auditory+acuity%22">Auditory acuity</searchLink><br />*<searchLink fieldCode="DE" term="%22Age+distribution%22">Age distribution</searchLink><br />*<searchLink fieldCode="DE" term="%22Speech+audiometry%22">Speech audiometry</searchLink><br />*<searchLink fieldCode="DE" term="%22Statistics%22">Statistics</searchLink><br />*<searchLink fieldCode="DE" term="%22Speech+perception%22">Speech perception</searchLink><br />*<searchLink fieldCode="DE" term="%22Data+analysis+software%22">Data analysis software</searchLink><br />*<searchLink fieldCode="DE" term="%22Hearing%22">Hearing</searchLink><br />*<searchLink fieldCode="DE" term="%22Transducers%22">Transducers</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: The purpose of the present study was to determine whether standard and high-frequency transducers influence test scores on clinically used speech-in- noise (SIN) assessments, such as the Word-In-Noise (WIN) and QuickSIN tests. Method: Sixteen individuals whose hearing thresholds were within normal limits (≤ 25 dB HL at 0.5, 1, 2, and 4 kHz), and nine individuals with sensorineural hearing loss participated in this research. Hearing thresholds were obtained at extended high frequencies in adults with normal hearing. The WIN and QuickSIN tests were administered to only one ear. These tests were conducted using the RadioEar IP30 and RadioEar DD450 transducers. Results: There were no significant differences in the WIN and QuickSIN test scores between the IP30 and DD450 transducers in both groups. Analysis of WIN and QuickSIN test scores of individuals whose thresholds were within normal limits while controlling for age and extended high-frequency hearing thresholds showed no significant effect of the transducer, suggesting that these factors did not influence the test scores. Conclusion: The findings of this study suggest that both IP30 inserts and DD450 headphones are suitable for use in WIN and QuickSIN testing. [ABSTRACT FROM AUTHOR] |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=asx&AN=194359730 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1044/2025_AJA-25-00248 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 8 StartPage: 557 Subjects: – SubjectFull: Auditory perception testing Type: general – SubjectFull: Noise Type: general – SubjectFull: Research funding Type: general – SubjectFull: Data analysis Type: general – SubjectFull: Sensorineural hearing loss Type: general – SubjectFull: Product design Type: general – SubjectFull: Audiometric equipment Type: general – SubjectFull: Treatment effectiveness Type: general – SubjectFull: Descriptive statistics Type: general – SubjectFull: Audiometry Type: general – SubjectFull: Auditory acuity Type: general – SubjectFull: Age distribution Type: general – SubjectFull: Speech audiometry Type: general – SubjectFull: Statistics Type: general – SubjectFull: Speech perception Type: general – SubjectFull: Data analysis software Type: general – SubjectFull: Hearing Type: general – SubjectFull: Transducers Type: general Titles: – TitleFull: The Effect of Transducer High-Frequency Output on Clinically Used Speech Recognition in Noise Tests. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Veeranna, Sangamanatha Ankmnal – PersonEntity: Name: NameFull: Chapmana, Jennifer IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 06 Text: Jun2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 10590889 Numbering: – Type: volume Value: 35 – Type: issue Value: 2 Titles: – TitleFull: American Journal of Audiology Type: main |
| ResultId | 1 |