Academic Journal
Active Suppression of Differential Light Shift Drift in an Atom Gravimeter.
| Title: | Active Suppression of Differential Light Shift Drift in an Atom Gravimeter. |
|---|---|
| Authors: | Xu, Wei-Hao1,2 (AUTHOR), Chen, Xi1,2,3 (AUTHOR) lijinting@apm.ac.cn, Li, Jin-Ting1,2,3 (AUTHOR), Zhang, Dan-Fang1,2,4 (AUTHOR), Wang, Wen-Zhang1,2 (AUTHOR), Wei, Jia-Yi1,2 (AUTHOR), Zhong, Jia-Qi1,3 (AUTHOR), Tang, Biao1,4 (AUTHOR), Zhou, Lin1 (AUTHOR), Li, Run-Bing1,3 (AUTHOR), Wang, Jin1,3,4 (AUTHOR), Zhan, Min-Sheng1,3,4 (AUTHOR) mszhan@apm.ac.cn |
| Source: | Sensors (14248220). Mar2026, Vol. 26 Issue 5, p1620. 14p. |
| Subject Terms: | *Gravimeters (Geophysical instruments), *Optical modulators, *Gravimetry, *Interferometry, *Measurement |
| Abstract: | Differential light shift (DLS) is an important error term that limits the atom interferometer's measurement precision, especially for the case of the electro-optic modulator (EOM)-based scheme, where multiple laser sidebands exist, and their ratios are hard to control synchronously. This article carried out an experimental and theoretical study on this subject. By conducting long-term gravity measurement, we find that the gravity exhibits drifts of about 13.13 μGal, and is strongly correlated to the Raman laser's sidebands. A model of the DLS-induced gravity error is established and a DLS compensation method is proposed to suppress the gravity drift to 2.54 μGal. Besides the compensation method, we propose a Dual-Sideband Ratio Locking scheme to more robustly eliminate the gravity measurement drift. By feeding back to both the EOM microwave power and the tapered amplifier's temperature, this method locks both the ±1 order sideband to a stability level of 10 − 5 , which corresponds to a gravity error of less than 0.1 μGal. Long-term gravity measurement is carried out after the locking method, showing a long-term stability of 1.6 μGal. The proposed methods will benefit the suppression of the DLS effect for high-precision atom interference measurement. [ABSTRACT FROM AUTHOR] |
| Database: | Academic Search Index |
| FullText | Text: Availability: 0 CustomLinks: – Url: https://resolver.ebsco.com/c/fiv2js/result?sid=EBSCO:asx&genre=article&issn=14248220&ISBN=&volume=26&issue=5&date=20260301&spage=1620&pages=1620-1633&title=Sensors (14248220)&atitle=Active%20Suppression%20of%20Differential%20Light%20Shift%20Drift%20in%20an%20Atom%20Gravimeter.&aulast=Xu%2C%20Wei-Hao&id=DOI:10.3390/s26051620 Name: Full Text Finder (for New FTF UI) (ns324271) Category: fullText Text: Full Text Finder MouseOverText: Full Text Finder |
|---|---|
| Header | DbId: asx DbLabel: Academic Search Index An: 192639047 RelevancyScore: 1411 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 1411.07177734375 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Active Suppression of Differential Light Shift Drift in an Atom Gravimeter. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Xu%2C+Wei-Hao%22">Xu, Wei-Hao</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Chen%2C+Xi%22">Chen, Xi</searchLink><relatesTo>1,2,3</relatesTo> (AUTHOR)<i> lijinting@apm.ac.cn</i><br /><searchLink fieldCode="AR" term="%22Li%2C+Jin-Ting%22">Li, Jin-Ting</searchLink><relatesTo>1,2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhang%2C+Dan-Fang%22">Zhang, Dan-Fang</searchLink><relatesTo>1,2,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wang%2C+Wen-Zhang%22">Wang, Wen-Zhang</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wei%2C+Jia-Yi%22">Wei, Jia-Yi</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhong%2C+Jia-Qi%22">Zhong, Jia-Qi</searchLink><relatesTo>1,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Tang%2C+Biao%22">Tang, Biao</searchLink><relatesTo>1,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhou%2C+Lin%22">Zhou, Lin</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Li%2C+Run-Bing%22">Li, Run-Bing</searchLink><relatesTo>1,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wang%2C+Jin%22">Wang, Jin</searchLink><relatesTo>1,3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhan%2C+Min-Sheng%22">Zhan, Min-Sheng</searchLink><relatesTo>1,3,4</relatesTo> (AUTHOR)<i> mszhan@apm.ac.cn</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Sensors+%2814248220%29%22">Sensors (14248220)</searchLink>. Mar2026, Vol. 26 Issue 5, p1620. 14p. – Name: Subject Label: Subject Terms Group: Su Data: *<searchLink fieldCode="DE" term="%22Gravimeters+%28Geophysical+instruments%29%22">Gravimeters (Geophysical instruments)</searchLink><br />*<searchLink fieldCode="DE" term="%22Optical+modulators%22">Optical modulators</searchLink><br />*<searchLink fieldCode="DE" term="%22Gravimetry%22">Gravimetry</searchLink><br />*<searchLink fieldCode="DE" term="%22Interferometry%22">Interferometry</searchLink><br />*<searchLink fieldCode="DE" term="%22Measurement%22">Measurement</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Differential light shift (DLS) is an important error term that limits the atom interferometer's measurement precision, especially for the case of the electro-optic modulator (EOM)-based scheme, where multiple laser sidebands exist, and their ratios are hard to control synchronously. This article carried out an experimental and theoretical study on this subject. By conducting long-term gravity measurement, we find that the gravity exhibits drifts of about 13.13 μGal, and is strongly correlated to the Raman laser's sidebands. A model of the DLS-induced gravity error is established and a DLS compensation method is proposed to suppress the gravity drift to 2.54 μGal. Besides the compensation method, we propose a Dual-Sideband Ratio Locking scheme to more robustly eliminate the gravity measurement drift. By feeding back to both the EOM microwave power and the tapered amplifier's temperature, this method locks both the ±1 order sideband to a stability level of 10 − 5 , which corresponds to a gravity error of less than 0.1 μGal. Long-term gravity measurement is carried out after the locking method, showing a long-term stability of 1.6 μGal. The proposed methods will benefit the suppression of the DLS effect for high-precision atom interference measurement. [ABSTRACT FROM AUTHOR] |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=asx&AN=192639047 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.3390/s26051620 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 14 StartPage: 1620 Subjects: – SubjectFull: Gravimeters (Geophysical instruments) Type: general – SubjectFull: Optical modulators Type: general – SubjectFull: Gravimetry Type: general – SubjectFull: Interferometry Type: general – SubjectFull: Measurement Type: general Titles: – TitleFull: Active Suppression of Differential Light Shift Drift in an Atom Gravimeter. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Xu, Wei-Hao – PersonEntity: Name: NameFull: Chen, Xi – PersonEntity: Name: NameFull: Li, Jin-Ting – PersonEntity: Name: NameFull: Zhang, Dan-Fang – PersonEntity: Name: NameFull: Wang, Wen-Zhang – PersonEntity: Name: NameFull: Wei, Jia-Yi – PersonEntity: Name: NameFull: Zhong, Jia-Qi – PersonEntity: Name: NameFull: Tang, Biao – PersonEntity: Name: NameFull: Zhou, Lin – PersonEntity: Name: NameFull: Li, Run-Bing – PersonEntity: Name: NameFull: Wang, Jin – PersonEntity: Name: NameFull: Zhan, Min-Sheng IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 03 Text: Mar2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 14248220 Numbering: – Type: volume Value: 26 – Type: issue Value: 5 Titles: – TitleFull: Sensors (14248220) Type: main |
| ResultId | 1 |